id bop kill line choke line

Stack Configuration 1. Using the BOP configuration …

‘Three Pipe Rams, One Annular Preventer, one Kill Line and one Choke line valve’. Annular Preventer: 22 gallons to close. 20 gallons to open. Pipe ram: 16 gallons to close. 13 gallons to open Kill and Choke Line Valves: 1.5 gallon to close. 1.5 gallon to open 5.

-Well Control Equipment_

Each line should have two full-bore valves of which one valve of each line is remote hydraulically operated. Both lines should be connected to the kill and choke line manifold (see Section 4.6.2). When dual purpose kill and choke lines are not employed, the BOP

Choke and Kill Line Hose Used as Flexible Connection

The specifiion of choke and kill line hose Hose code ID OD Working pressure Test pressure Min burst pressure Min bending radius Weight Inch mm mm MPa psi MPa psi MPa psi m Kg/m CKL-01 2 50.8 99 34.5 5000 69.0 10000 103.5 15000 1.2 15.0 CKL-02 2.5

BOP Control Hose - Jingbo Petroleum Machinery CO. LTD

Well Control Professional Tube BOP Control Line ——GNG High-pressure Fire-resistant and Heat-insulation Hose Assely Patent No.:ZL 92 104811.4 HeBei Jingbo Petroleum Machinery Co., Ltd.---- …

List of Appendices - BC Oil and Gas Commission

Kill line must be a minimum nominal diameter of 50.8mm throughout. Flanged pipe connections must be used from the drilling spool down to and including the connection to the choke manifold. The remainder of the choke manifold may contain 14MPa.

How to Pass the IWCF Supervisor Well Control Exam – …

Minutes 0-40: The first 40 minutes or so of the exam was going over the “instructions” to the driller as well taking the slow pump rates (SPR) and choke line friction (CLF) values. Minutes 40-70: During this time frame, the driller starts actually drilling the well and the supervisor (Level 4 candidate) is actually out of the simulator room.

New 540hp Mobile Drilling / Heavy Workover Rig for …

C/W Choke line valves and Kill line Valves Choke Manifold 3 1/8” x 5,000 psi Choke Manifold Two (2) Manual Choke BOP Closing Unit 4 station, 3000 PSI, 120 Gallon 10 Bottles (12 gallon bottles) Power Generation : Two (2) erpillar C-15 – (50 Hz) (355 kW)

Directive 036: Drilling Blowout Prevention Requirements and …

Directive 036 Directive 036: Drilling Blowout Prevention Requirements and Procedures (March 2019) i Release date: March 14, 2019 Effective date: March 14, 2019 Replaces previous edition issued January 31, 2018. Drilling Blowout Prevention Requirements and

Blowout preventer - Wikipedia

Use Blowout preventers come in a variety of styles, sizes and pressure ratings. Several individual units serving various functions are coined to compose a blowout preventer stack. Multiple blowout preventers of the same type are frequently provided for redundancy, an important factor in the effectiveness of fail-safe devices.

Well control - Stack Configuration 1. Using the BOP | …

‘Three Pipe Rams, One Annular Preventer, one Kill Line and one Choke line valve’. Annular Preventer: 22 gallons to close. 20 gallons to open. Pipe ram: 16 gallons to close. 13 gallons to open Kill and Choke Line Valves: 1.5 gallon to close. 1.5 gallon to open 5.

Dog Type 2™ Flange Type-E™ Flange Type-H™ Flange Type-H …

Seawater Line – 7.5K / 7.25"x6.0"4 Line (Choke, Kill, Hydraulic – 5K / 2.5" Sch80 (Duplex SS) Other All lines are 90 degrees apart with split hydraulic lines. NO

Blow Out Preventer for Offshore Drilling Rig – Oilfield …

Blow Out Preventer (BOP) for Drilling Oil Rig Small Size for Internet Use (600 pixel width) License: Royalty Free Resolution: 399 x 600 px ( 1.3" x 2" @ 300 dpi ) $3.00 DOWNLOAD

Drill Flex USA | Rotary Hose, Choke and Kill Hose, BOP …

Drill Flex offers a full line high-quality inexpensive drilling hoses, including Choke & Kill hoses, Blowout preventers (BOPs), Slim hole rotary hoses, Grade D rotary hoses, Grade E rotary hoses, Vibrator hoses, Cementing hoses and more.

Coflexip Type Hoses Choke Kill Lines China Manufacturer …

Coflexip type choke kill hose, 3", 45 feet to India offshore service clients Oilwell supplies 1 nos choke kill line 3-1/8", 45 feet long, API Flanges ends to Singapore clients Rotary hoses and choke kill hose lines 3" x 30'' Length with hydrostatic test certifie

Blowout Preventers - Drilling Engineering - Netwas Group …

2020/8/5· The choke line carries the mud and kick fluid from the BOP stack to the choke device. The kill line is a backup choke line. The choke and kill lines may be used to primp mud directly into the annulus if necessary, although the kill line usually performs this function.

Basic Well Control - LinkedIn SlideShare

Choke Line Friction (CLFP) • Used to determine the amount by which the casing pressure is to be adjusted to maintain BHP = FP when starting the pumps on a kill operation. We reduce the SICP by the amount of CLFP to make allowances for the back pressure imposed by the CLFP.

coflexip choke kill hose supply

A Continuous Flexible 15,OOO-psi Choke and Kill Line System From the BOP Flexible pipes, such as those manufactured by Coflexip since 1972, have Drilling Work Over Manual-2014 Latest 20141228- Important manual to supply products to Saudi choke and kill lines, choke manifolds, gas (choke and kill hoses acc. to API Spec. 16C

Subsea Presentation | Gases | Mechanical Engineering | …

Removing trapped gas from the BOP Step # 2: - Displace choke line to water or base oil to BOP stack taking returns up the kill line. - Do not over displace. - Close the fail safe valves on the kill line. 54 Removing trapped gas from the BOP Step # 3: - Vent the 55

Drilling Structures 800hp Rig for sale, Land Rigs for Sale, …

Rams for above preventers : Pipe and blind rams, pipe rams for 3 1/2", 4 1/2", 5 1/2". Kill and Choke Lines Choke line from BOP stack to choke manifold : One each: Coflexip (protected type) Choke Manifold Choke Manifold : 5000 PSI Choke Manifold outlet

Suppliers Matching choke kill (Product And Company,US …

139 results matching choke kill Sort by relevance nuer of matching shipments recency weighted matching shipments specialization (% matching) expertise (length of time shipped) total matching shipment volume (kg) supplier name (A-Z) supplier name (Z-A) nuer of total shipments (high-low) nuer of total shipments (low-high)

SUMMARY OF BLOWOUT PREVENTER (BOP) FAILURE MODE …

SUMMARY OF BLOWOUT PREVENTER (BOP) FAILURE MODE EFFECT CRITICALITY ANALYSES (FMECAs) FOR THE BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT 2650788-FMECA-FS-E3 1 Issued for BSEE Review 4-29-2013 Report

offers from coflex hose manufacturers, suppliers, …

coflex hose Manufacturers Directory 3 million global importers and exporters coflex hose suppliers, manufacturers, wholesalers, coflex hose sellers, traders, exporters and distributors from China and around the world at EC21

Scott Holt / phone - 713.829.2649 / email - …

Mactech ID Cutter BTI Cryogenic Pipe Freezing System Well-Contained Branding OTC 2014 Subsea BOP Losing Oil Well Ballooning & Fingerprinting Wellhead Choke Line WWC Back Panel Display - OTC 2013 How To Build A Killsheet

Subsea stack alignment method - Hydril USA …

7. The method of claim 1, wherein the feed-thru component is at least one of a choke line, a kill line, a wellbore, a hot stab line, a multiplex hydraulic line, a hydraulic line, an electrical line, or a blowout preventer operating line. 8.

Berbagi Pengetahuan: BOP (Blow Out Preventer)

Kill Line bekerja pada BOP Stack biasanya berlawanan berlangsung dengan choke manifold ( dan choke line ). Lumpur berat dipompakan melalui kill line kedalam lumpur bor sampai tekanan hidrostatik lumpur dapat mengiangi tekanan formasi.

INTEGRATED® OEM ELASTOMER is an established OEM …

Choke & Kill Manifolds API Valves (FC, FLS, etc.) Pulsation Dampeners PPD: Production Pulsation Dampeners Sizes: 1, 2.5, 5, 10 & 20 gal units up to 7,500 psi DPD: Drilling Pulsation Dampeners Sizes: 10 & 20 gal units up to 7,500 psi BOP Annular

MINISTERE DE L’ENSEIGNEMENT SUPERIEURE ET DE LA RECHERCHE

Fig.II.16 Choke et kil manifold 20 Fig.II.17 Duse réglable manuelle 21 Fig.II.18 Duse Cameron commandée à distance 22 Fig.II.19 choke panel 22 Fig.II.20 Schéma d’un séparateur atmosphérique 23 Fig.III.1 les lignes de contrôles inutilisés 28 Fig.III.2

R-156 BOP

TO KILL LINE J L G K TO CHOKE LINE OPEN CLOSE A 13 5/8" 10M FLANGE RIG 159 BOP STACK-UP SYM CAC159-A-005-00-RO B CAC159-A0051/1 I:\RIG DRAWINGS & DIAGRAMS\R-159\R-159 (CAD)\R-159_BOP N/A J.D.B. 07/12/17 Tel: 405-577